How to specify a
stretch ceiling.
The six-step path from concept to an approved submittal — CSI section, membrane selection, fire documentation, lighting, and the package your contractor hands in.
Six steps, start to submittal.
Start from the CSI section
Stretch ceilings live in Section 09 54 00 — Specialty Ceilings (stretched-fabric systems are also indexed under 09 54 43). Our basis-of-design specification is written in standard 3-part CSI format and drops into your project manual as-is.
Choose the membrane finish
Six white finishes — matte, satin, gloss, transparent frost, warm and cold translucent — plus printed and lacquer options, in seamless widths for most rooms. Each finish has its own membrane data sheet with physical, optical and fire data.
Browse membranes → · All seven membrane data sheets are compared on the membrane data page.
Document the fire performance
Each white finish was tested to ASTM E84 at Intertek — flame spread index 5 to 15 and smoke developed 250 to 300, reported per finish. The reports state the indices; the code comparison for your project is made by the design professional and the local authority.
Design the lighting
For backlit and luminous ceilings, translucent membranes transmit 42% diffused light — the number your lighting consultant needs for fixture spacing behind the membrane. Perimeter, linear, cove, star and printed systems each have their own detail pages.
Assemble the submittal package
A complete stretch ceiling submittal contains: the edited Section 09 54 00 spec, the membrane data sheet for the selected finish, per-finish fire test data, light transmission data for lit assemblies, warranty terms, and the care & maintenance guide. We assemble this as one package for your project.
Send it for review
Our team edits Section 09 54 00 around your project, reviews shop drawings before fabrication, and runs lunch-and-learn sessions at your studio. Installation is performed by CeilEx-trained dealers.
What spec writers ask us.
What CSI MasterFormat section covers stretch ceilings?
Section 09 54 00, Specialty Ceilings. Stretched-fabric ceiling systems are also indexed under 09 54 43. The CeilEx basis-of-design specification is written for 09 54 00 and cross-references 09 54 43.
What goes into a stretch ceiling submittal package?
The project-edited CSI specification, the membrane data sheet for the selected finish, per-finish ASTM E84 fire test data, light transmission data when the ceiling is backlit, warranty terms, and the care and maintenance guide.
How is fire performance documented?
Each white CeilEx membrane finish was tested to ASTM E84 at Intertek, with flame spread indices of 5 to 15 and smoke developed of 250 to 300 reported per finish in document FPD-100. The reports state the indices; the code comparison for your project is made by the design professional and the local authority.
Who reviews shop drawings and supports installation?
CeilEx reviews shop drawings before fabrication and supports the installing dealer through the job. Installers are trained at the CeilEx academy in Dania Beach, Florida, and graduates carry lifetime technical support.